Installation Overview

We install Storm Shelters across multiple counties in Texas

ArmourGuard installs above ground storm shelters across North, East, and West Texas. Our service area spans from Denton County and Wise County, west through Parker County and the Weatherford area, south into Tarrant and Johnson Counties including Mansfield, and east through Hunt County and Lamar County into East Texas communities such as Paris and surrounding areas.

We regularly install storm shelters in:

  • Denton County
  • Wise County
  • Tarrant County
  • Parker County
  • Johnson County
  • Collin County
  • Hunt County
  • Lamar County
  • And surrounding counties across North and East Texas

Many customers with existing homes choose to put their ArmourGuard Storm Shelter in their existing garage.  Some do not have that luxury and instead put the shelter outside on an engineered concrete slab.

According to ICC 500 and FEMA P-361 standards, the foundation for a residential safe room must meet the following minimum requirements:
- Concrete Strength: A minimum compressive strength of 3,000 to 4,000 PSI is required to ensure proper anchor bolt pull-out resistance.
- Minimum Thickness: The slab must be at least 3.5 to 4 inches thick. ArmourGuard may recommend a 6-inch thickness for standalone pads to provide better stability.
- Steel Reinforcement: Slabs must contain steel reinforcement to prevent structural failure under tension. Typical standards include:
          - Rebar: No. 4 bars spaced at a maximum of 18 inches on center in two perpendicular directions.
          - Mesh: 6x6 – W1.4 x W1.4 welded wire reinforcement.

Slab Geometry: The foundation should ideally extend at least 12 inches beyond the shelter's footprint on all sides to provide adequate mass for anchoring.

All of our above ground shelters are anchored to your engineered concrete foundation with Hilti Anchors, every 12 inches around the perimiter of the shelter.  This exceeds standards set by FEMA.  

Shield 4x4 Shelter

Minimum Slab Specification

  • Shelter size: 4 ft x 4 ft
  • Minimum slab size: 5 ft x 5 ft
  • Concrete strength: 3,000 PSI minimum
  • Thickness: 4 inches minimum
  • Reinforcement: steel mesh or #4 rebar
  • Existing slab must be level and structurally sound

Recommended Slab Specification

  • Slab size: 6 ft x 6 ft
  • Concrete strength: 4,000 PSI
  • Thickness: 6 inches
  • Reinforcement: #4 rebar, 12 inches on center
  • Perimeter foundation: 8 inches wide x 8 inches deep

Stronghold 4x6 Shelter

Minimum Slab Specification

  • Shelter size: 4 ft x 6 ft
  • Minimum slab size: 5 ft x 7 ft
  • Concrete strength: 3,000 PSI minimum
  • Thickness: 4 inches minimum
  • Reinforcement: steel mesh or #4 rebar
  • Existing slab must be level and structurally sound

Recommended Slab Specification

  • Slab size: 6 ft x 8 ft
  • Concrete strength: 4,000 PSI
  • Thickness: 6 inches
  • Reinforcement: #4 rebar, 12 inches on center
  • Perimeter foundation: 8 inches wide x 8 inches deep

Fortress 4x8 Shelter

Minimum Slab Specification

  • Shelter size: 4 ft x 8 ft
  • Minimum slab size: 5 ft x 9 ft
  • Concrete strength: 3,000 PSI minimum
  • Thickness: 4 inches minimum
  • Reinforcement: steel mesh or #4 rebar
  • Existing slab must be level and structurally sound

Recommended Slab Specification

  • Slab size: 6 ft x 10 ft
  • Concrete strength: 4,000 PSI
  • Thickness: 6 inches
  • Reinforcement: #4 rebar, 12 inches on center
  • Perimeter foundation: 8 inches wide x 8 inches deep